Automatic Film Applicator Compact
PRODUCT DESCRIPTION
The AFA Compact is an entry level film applicator that accepts charts up to A4 size. Application speed can be set from 1 to 150 mm/s. The Compact is suitable for both wire wound rod applicators and block applicators. Operating is easy through the standard TQC operating interface. The AFA Compact is available with a glass bed or a perforated vacuum bed.
| Traverse Speed | 1 – 150 mm/s / 0.03 – 5.90 inch/s |
|---|---|
| Speed Accuracy | < 1% |
| Stroke length | 250 mm / 9.84 in |
| Stroke Length Accuracy | <1 mm (0,025 mm/step) / <0.03 inch |
| Max. Test Chart Size | DIN A4 |
| Max. Test Substrate Thickness | 8 mm / 0,31 inch (incl coating) |
| Max. Size of Panel | 300x200x8 mm / 11.81×7.87×0.31 inch |
| Max. height film applicators | 40 mm / 1.57 inch |
| Min. Wire Bar Length | >220 mm / >8.66 inch |
| Wire Bar Diameter | 6 – 12,7 mm / 0.23 – 0.5 inch |
| Volume Drip Pan | 30 ml |
| Min. Vacuum | -100 mbar |
| Diameter vacuum holes | 1,3 mm / 0.05 inch |
| Distance vacuum bed holes | 22 mm / 0.86 inch |
| Number of holes in vacuum bed | 117 |
| Vacuum Connection | 6 mm / 0.23 inch Quick Connect |
| Dimensions | 335x400x190 mm / 13.18×15.74×7.48 inch |
| Mass | 12,5 kg / 27.55 lbs |
| Power | 110 – 240VAC / 50 – 60Hz |
| Power Consumption | Max. 40 Watt |
| Display | 128 x 64 pixels graphical LCD, 70 mm x 40 mm, white illuminated, heated |
| Languages | English |

Documents (EN) : Datasheet
Looking for the other Film Application devices.
Clean
Supplied with drip pan and paper holder for easy cleaning.
Charts
Charts up to A4 size.
Triple i Control
Operating is very easy with the Triple i operating interface. This unique systems guide the operator through the interface of TQC lab-machines. At each step of the operating menu the interface detects which buttons are active and indicates these by means of an illuminated red centre. This results in a very intuitive operating system which is enhanced with information on the machine’s display.
Traverse Speed
Accurate traverse speed 1 – 150 mm/s / 0.03 – 5.90 in/s and infinite adjustable.
Tools
Compatible with a large range of application tools.
AUTOMATIC FILM APPLICATOR COMPACT
MODEL
Automatic Film Applicator Compact Glass Bed – AB3650
This model keeps the test charts in position via means of an glas bed which is produced out of ultra-flat hardened float glass. Test coating test charts or other specimen are kept in place via a manual stainless steel clamping mechanism. For cleaning purposes the glass bed can easily be removed without the use of any tools.
AB3650 can be used with hiding power charts, opacity charts, spreading rate charts , brushout cards, metal test panels, paper- or cardboard coating test charts, penetration charts ,plastic or wooden sample panels, foils or other flexible surfaces with a max. dimension of Din A4 or 210 x 297 mm. or 8.3 x 11.7 inches.
Automatic Film Applicator Compact Vacuum Bed – AB3655
This model keeps the test charts in position via means of an ultra-flat perforated vacuum bed made of hard-anodized aluminium. A stainless steel clamp is also fitted to fix the draw down charts without vacuum. For cleaning purposes the vacuum plate can easily be removed without the use of any tools.
AB3655 can be used with hiding power charts, opacity charts, spreading rate charts, metal test panels, paper- or cardboard coating test charts, brushout cards , penetration charts, plastic or wooden sample panels, foils or other flexible surfaces with a max. dimension of Din A4 or 210 x 297 mm. or 8.3 x 11.7 inches.
[] Paint research & development laboratories use compact film applicators to produce consistent test-charts for research after different formulations. Parameters such as opacity, spreading rate , colour and hiding power etc. needs to evaluated at controlled film thickness.
[] Manufacturers of raw materials for the paint & coating industry such as binders, pigments, additives, colourants, solvents and resins need reproducible sample charts in order to define the effect of their products in a paint formulation in their R&D laboratory.
[] The industry is anxiously searching for better and environmental friendly batteries. Thin film technology plays and important role in this research. Automatic film applicators are used by these laboratories to apply thin films such as electrolyte of thin metal sheets.
[] Create reproducible samples measure the properties of cosmetics and skincare products such as hardness, break strength, consistency , compaction strength, hiding power and opacity, spread ability, stickiness , drying and curing time, colour, gloss etc..
[] Both in R&D and QC of the adhesive industry test samples with an accurate film thickness are crucial in order to define and guarantee the functionality and strength of the adhesive materials.
Customer Service
Free Installation & Training for order amount much than 10,000 THB
DELIVERY SCHEDULE
Differentiate for each goods. Please contact us for information.
1-YEAR OF WARRANTY
For Electric Tester.

Zahn cup อุปกรณ์วัดความหนืด (conforms to ASTM D4212) 






รีวิว
ยังไม่มีบทวิจารณ์